JUMAG hot water boiler NEMO

Do you need hot water? Then you’ve come to the right place. Thanks to its compact design, the JUMAG NEMO hot water boiler takes up little space and scores with minimum maintenance and maximum energy efficiency. It is equally at home in office buildings, hospitals, hotels and residential buildings.

Also available for hire

Advantages of the JUMAG NEMO hot water boiler

Space-saving

Thanks to its compact design, the NEMO takes up less space than conventional boilers and offers you additional room for your ideas.

Low costs

The NEMO can be operated efficiently. It utilises a closed water circuit. This means you not only save on the purchase costs, but also on the running costs for water. In addition, there is no need for expensive water treatment.

Low maintenance effort

You do not need any peripheral devices such as ASG or WAM. This makes operating the NEMO particularly straightforward and requires only minimal maintenance.

Basic equipment NEMO

  • Hot water boiler (DG series)
  • Burner
  • Double-walled pressure vessel in the design of a small water chamber boiler
  • Self-explanatory touch screen control
  • Integrated electrical cabinet
  • Safety components: Safety valve, overpressure cut-off, minimum pressure cut-off, hot water overtemperature cut-off, low water cut-off, flow monitoring

Not included in the scope of delivery:

  • Circulation pump
  • Expansion vessel
JUMAG Dampferzeuger Heißwasserkessel NEMO
Touch screen control
Integrated electrical cabinet
Lots of safety components
Burner
Components made from high-quality stainless steel
Hot water boiler

JUMAG NEMO hot water boiler in detail

Functionality of the hot water boiler

Why do JUMAG hot water boilers require minimal maintenance and boast maximum energy efficiency? They utilise a closed water circuit and run without peripheral devices.

The hot water generator is part of a closed system in which pressurised water is continuously circulated by the boiler pump.

The burner is controlled depending on the flow temperature.

Heat is transferred from the flue gas via the hot water generator to the water through multiple flue gas ducts.

As the system pressure of the entire hot water network is constantly above the saturation steam pressure, water temperatures of 110°C or more are reached in the boiler.

Technical data NEMO

NEMO 260NEMO 500
PED 2014/68/EUCategory IIICategory III
Max. Operating pressure (PS)6 barg13 barg
Max. Working Pressure5 barg12 barg
Test pressure pressurised vessel (PT)23 barg22,2 barg
Heat load85 - 175 kW360kW
Heat output77 -157 kW340kW
Total volume (V)49 Litres215 Litres
Max. permitted temperature (TS)185 °C195 °C
Heat-up time in minutes510
Max. Oil flow rate (11,8 kWh/kg)14,8 kg/h30,5 kg/h
Max. Natural gas flow rate (10,35 kWh/m³)16,9 m³/h34,7 m³/h
Min. gas flow pressure17 mbarg20 mbarg
Flue gas connection (inside diameter)301 mm301 mm
Exhaust mass flow0,08 kg/s0,17 kg/s
Min. flue draught (at 150 °C)5 Pa5 Pa
Electrical connection400 V / 50 Hz400 V / 50 Hz
Electrical connected load3,2 kW3,2 kW
Ambient temperature5 °C - 35 °C5 °C - 35 °C
Leeweight700 kg1300 kg
Noise level58 dbA (Oil)
61 dbA (Gas)
76 dbA (Oil)
76 dbA (Gas)
Gas connection1"1"
Flow connection (PN16)DN25DN25
Return flow connection (PN16)DN25DN25
Safety valve connection Götze 6 barg (PN16)DN32DN25

Areas of application and use cases of the NEMO

Find out why the NEMO hot water boiler exists, what it is best used for and what the difference is to a steam generator in our blog post .

-> A novelty at JUMAG: NEMO hot water boiler